G-KH8J98NK4T

25KW - MONOBLOC Type DC Inverter EVI Air to Water Heat Pump

  • Product Code: SLS-85CHW/SF
  • Availability: In Stock
ErP Level A+++ | -35°C Low Temp Heating | 50°C High Temp Cooling

SOLLIS SF Series DC Inverter Air to Water Heat Pump System Diagram

Top Quality Configurtion

Unit Mainly Components Includes Panasonic Brand Rotary Twin-Cylinder EVI Low Temp Explosion-proof DC Inverter Compressor! Danfoss Brand Electric Expansion Valve! SANHUA Brand Four way valve! Sensata Brand Pressure Transducer! Wolong Brand Dc Motor! Hydrophilic Aluminium foil & Inner-Grooved Copper Evaporator! Refrigerant valve and De-Ice Heater so on parts.

Model SLS-85CHW/SF
Power Supply V/Hz 400V/30~85Hz
ErP Level / SCOP 35 C A+++ / 4.48
ErP Level / SCOP 55 C A++ / 3.43
1# Heating Conditions Ambient Air temp 7°C Water inlet 30°C Water outlet 35°C
Heating (1) Rated Heating Capacity (7°C/35°C) kW 25
Rated Input Power kW 6.1
SCOP 4.36
2# Heating Conditions Ambient Air temp 7°C Water inlet 50°C Water outlet 55°C
Heating (2) Rated Heating Capacity (7°C/55°C) kW 25
Rated Input Power kW 6.16
SCOP 4.12
3# Heating Conditions Ambient Air temp 2°C Water inlet 30°C Water outlet 35°C
Heating (3) Rated Heating Capacity (2°C/35°C) kW 24.1
Rated Input Power kW 7.2
SCOP 4.05
4# Heating Conditions Ambient Air temp 2°C Water inlet 50°C Water outlet 55°C
Heating (4) Rated Heating Capacity (2°C/55°C) kW 23.9
Rated Input Power kW 7.44
SCOP 3.9
5# Heating Conditions Ambient Air temp -7°C Water inlet 30°C Water outlet 35°C
Heating (5) Rated Heating Capacity (-7°C/35°C) kW 21.6
Rated Input Power kW 6.55
SCOP 3.5
6# Heating Conditions Ambient Air temp -7°C Water inlet 50°C Water outlet 55°C
Heating (6) Rated Heating Capacity (-7°C/55°C) kW 21.3
Rated Input Power kW 8.49
SCOP 3.4
7# Heating Conditions Ambient Air temp -12°C Water inlet 36°C Water outlet 41°C
Heating (7) Rated Heating Capacity (-12°C/41°C) kW 18.5
Rated Input Power kW 8.9
SCOP 2.88
8# Heating Conditions Ambient Air temp -20°C Water inlet 36°C Water outlet 41°C
Heating (8) Rated Heating Capacity (-20°C/41°C) kW 14.2
Rated Input Power kW 9.5
SCOP 1.98
Cooling Conditions Conditions Ambient Air temp 35°C Water inlet 12°C Water outlet 7°C
Cooling Rated Cooling Capacity (37°C/7°C) kW 19
Rated Input Power kW 7.25
EER 2.62
Refrigerant Type R32
Heating & Hot Water Temp °C 30°C - 60°C
Cooling Water Temp °C 7°C - 30°C
Outdoor Temperature limit °C -35°C - 60°C
Noise Level dB(A) 62
Net Weight/GrossWeight Kg 158/172
Net Dimension(L*W*H) mm 1238x435x1630
Packing Dimension(L*W*H) mm 1360*525*1760

According to EN14825, the data was tested in GSGapproved  low temperature air to water heat pump laboratory.

Write a review

Note: HTML is not translated!
    Bad           Good