ECHO-SF 300L Thermosiphonic Tanks
- Product Code: ECHO-SF 300L
- Availability: Delivery time - 45 days
G-KH8J98NK4T
Your shopping cart is empty!
Following the trends and needs of the market, SOLLIS has created a new line of thermosiphonic tanks. This brand new line will provide solutions to modern demands for even more money saving solar systems.
ECO-SF 300L
TYPE
TEHNICAL SPECIFICATIONS | |
Main Tanks Material | DC Sheet (En 10130/2006) |
Internal Anti-corrosion Protection | a) LIQUID enamel (DIN 4753-3), totally safe for public health (DIN 51032 & EN 1388-2) and b) magnesium anode (EN 12438) |
Welding | MIG |
Insulation | Hard polyurethane foame 48kg/mᶟ (DIN 53420), self-extinguishing (DIN 4102) |
Maximum Working Pressure for the Main Tank | 10 bar |
Test pressure for the Main Tank | 15 bar (EN 12976-1, 4.1.6) |
Maximum Working Pressure for the Jacket (r) | 3,2 bar |
Test Pressure for the Jacket (r) | 5 bar (EN 12976-1/2006, 4.1.6) |
Maximum Working Temperature of the Main Tank | 95°C |
Heating Element | Optional, upon request |
External Cover | Pre-painted galvanized steel sheet 0.5mm (EN 10204/2.2) |
ECO-SF model | 300 L | |
---|---|---|
Gross Capacity (lt) | 295 | |
A | Tanks Length (mm) | 1785 |
B | External Diameter (mm) | ø580 |
C | Main Tanks Diameter (mm) | ø480 |
Jackets Capacity (lt) | 19 | |
D | Flange Diameter (mm) | ø140 |
Weight (kg) | 100 | |
E | Pressure valve position protecting closed circuit | |
P | Inlet to fill exchangers solution and (optional) expansion vessel position | |
V | Pressure and temperature valve position protecting main tank | |
DWO | Domestic hot Water Outlet | |
DWI | Domestic cold Water Inlet | |
JO | Closed circuit cold water outlet | |
JI | Closed circuit hot water inlet |