Home / Houses
Houses
Heat pump, solar panels and fan coils for your house
In a house, the air-to-water heat pump, the solar panels and the terminals are designed together as one system: heating in winter, cooling and dehumidification in summer, domestic hot water all year round.
What matters
The building's needs
Heating and cooling from one system
Heating can be underfloor or by fan coils. Cooling and dehumidification come from the fan coils.
The right terminal for every room
Lolly in the living room, Zephir in the bedroom, EOS in the bathroom, Aris recessed in the wall or Brisell OC hidden in the false ceiling.
Domestic hot water
From the same heat pump, with a dedicated cylinder.
Fresh air
Heat recovery ventilation, where the house is airtight.
The solution
What we do for your house
- Room-by-room heat load calculation.
- Air-to-water heat pump and solar panels, sized together.
- The right terminal for each room, including the bathroom.
- Domestic hot water from the same heat pump, with a dedicated cylinder.
- Heat recovery ventilation where the house is airtight.
- App control with Wi-Fi+ or whole-home automation with Integra Benessere.

Recommended products
What we install here
The final choice depends on the building assessment and on the load calculation for each room.








Stages
How a project runs
First conversation
You tell us about the building and what you want. We ask for drawings, bills or details of the existing system, if you have them.
Site visit and assessment
On site we check the roof, the plant rooms, the electrical connection and the possible pipe and duct routes.
Design and quote
We propose the layout, the equipment and the work stages, with a price for each stage.
Installation and commissioning
We install, balance and commission the system, then train the people who use and manage it.
Frequently asked questions
What clients ask us
Can I keep underfloor heating?
Yes. The floor can stay for heating, while the fan coils handle cooling and dehumidification. The Vision+ thermostat also controls the underfloor system, for heating only.
How powerful should the terminal in a room be?
As a quick estimate, the Sollis 2024 catalog uses P = K × V, where V is the room volume in m³ and K is 25–30 W/m³ for cooling and 35–40 W/m³ for heating, depending on how well the house is insulated. For example, a 20 m² room with a 2.7 m ceiling is 54 m³, so roughly 1.4–1.6 kW for cooling. This is indicative; in the design we calculate the load room by room.
Can the solar panels cover all of the heat pumps' consumption?
It depends on the roof area and orientation, on the building's consumption and on the season. In winter the panels produce less and the heat pumps also run on grid power. We calculate the share the panels cover in the design, for your building.
Dedicated consulting
Tell us about your building
Tell us what you have: an apartment block, offices, an industrial building, a hotel, a guesthouse or a house. We come back with the questions we need answered, arrange a visit and prepare the quote.
Quotes and consulting
Tell us about your project
Phone+40 775 368 311 Emailinfo@e-sollis.com Request an assessmentOther buildings
See the other building types